Tel: +31 (0)10 258 1870 | Support: +31 (0)10 258 1876
Bellingham + Stanley 
ADP400 Series Polarimeters
Bellingham + Stanley


The ADP400 series come equipped with a full colour 4" high definition display meaning results are clearly visible to the operator. The expanded memory means that over 8000 measurements and recorded logs of instrument configuration can be saved and viewed or output to LIMS or Secure PDF. They are ideal for general purpose use in food, flavours, fragrance, pharmaceutical and chemical industries as well as within academia and research.

Calibration and configuration of the ADP400 can be password protected, accessible by keypad entry or, for convenience, using a fully configurable RFID tag. This, together with the audit trail, facilitates operation in environments conforming to FDA regulation 21 CFR Part 11 or GLP.
  • Patented XPC technology.
  • US / EP / BP / JP compliant.
  • Supports FDA regulation 21 CFR Part 11.
  • PHR-MEAN method with continuous or single-shot measurement modes.

ADP450 polarimeter with XPC technology:
The patented, on-board Peltier temperature control system for measuring optically active samples at stable temperatures.

ADP430 polarimeter:
For use where temperature control is not required or where a water bath or mathematical compensation is preferred.

Both models incorporate an easy-to-use methods system that gives convenient access to popular measurement types incl. continual measurement of optical rotation, specific rotation, concentration or inversion. The 'single-shot' measurement feature provides a snapshot result at any given time.
Technical Data:
Scales
Angular degrees:
ISS:
User scales / methods:

- 355 to + 355 °A
- 225 to + 225 °Z
100
Resolution
Angular degrees (°A):
ISS (°Z):

0.01 / 0.001 (selectable)
Accuracy
Angular degrees:
ISS:

± 0.010 °A
± 0.030 °Z
Precision (reproducibility)
Angular degrees:
ISS:

± 0.002 °A
± 0.005 °Z
User scales and methods:PHR-MEAN statistical, specific rotation, concentration, purity, sugar inversion, inversion (A-B) and user defined
Reading time:continuous measurement and display or single shot (selectable)
Tube length:10 to 200 mm
Sample illumination:LED (lifetime 100,000 h), sodium (589 nm)
Beam Ø:4 mm
Optical density:0.0 to 3.0 OD
Housing:PU foam with aluminium base
Interfaces:1 x USB (A), 1 x USB (B), 1 x Ethernet
Mains supply:100 to 240 V, 50 / 60 Hz
Max. Winkel:355.00 [°A]
Min. Zuckerscala:-225.00 [°Z]
Max. Zuckerscala:225.00 [°Z]
ADP400 Series Polarimeters  Bellingham + Stanley
Min. WinkelTypePUOrder No.CDC
-355.00ADP430151932971
-355.00ADP450154457681