Tel: +31 (0)10 258 1870 | Support: +31 (0)10 258 1876
 
Shaking Incubators VS 45 OI and VS 150 OI with Orbital Motion
LAUDA


In every-day laboratory use GFL shaking incubators are renowned as being extremely reliable and suitable for heavy-duty use. Specialised in gentle mixing as well as vigorous shaking, GFL shaking incubators are used for applications that require exactly reproducible orbital motions and temperatures of up to + 70 °C. Temperature constancy ± 0.2 °C, temporal.
They are preferred by standard and research laboratories for incubations, fermentations, homogenisations, chemical and biochemical reactions, enzyme and tissue studies, as well as for cultivating bacteria cultures.
  • Soft-touch keys with clear symbols. Fast and exact temperature setting, exact reproducibility of set values, such as temperature, shaking frequency and incubation time.
  • Microprocessor-controlled temperature regulation, PID type and RS232 interface.
  • Optimum temperature distribution throughout the cabinet interior.
  • Temperature setting and display: digital, LED, in 0.1 °C increments.
  • Temperature range: from 8 °C above ambient temperature to + 70 °C.
  • Serial cooling coil for applications below ambient temperature to connect to the water mains or to an external recirculating chiller.
  • Temperature range (operation with cooling coil): 20 to 70 °C, dependent on cooling media and ambient temperature.
  • Electronic monitoring of the temperature regulators triggers visual and acoustic alarms in case of fault. The heating is switched off, the cause of the fault is shown on the LED display.
  • Silent and robust shaking mechanism with gentle start-up and even orbital motion, independent of load, set shaking frequency and incubation time, due to microprocessor-technique.
  • The microprocessor-controlled timer displays continuously the current remaining running time of the incubation time and signals acoustically its expiry.
  • Over-temperature cut-out: electronical / dependent on the set value,
and electro-mechanical, under-temperature cut-out: electronical, max. 9.9 °C below set temperature.
  • The units bear the CE mark.
  • Supplied without accessories.
Mains supply:230 V, 50 to 60 Hz, 800 W
The outer housings are made of powder-coated, electrolytically galvanised sheet steel. Interior cabinet, the insides of the doors and the shaking platform are made of st. steel.
  • Incl. frame permitting use of two shaking trays.

Model VS 45 OI:
Acrylic glass window, approx. 45 l capacity, 2 shaking trays, for vessel height of more than 150 mm 1 shaking tray.

Model VS 150 OI:
Acrylic glass windows, approx. 150 l capacity, 2 shaking trays, for vessel height of more than 200 mm 1 shaking tray.
Shaking frequency VS 45 OI:20 to max. 250 min-1
Shaking frequency VS 150 OI when loading bottom / both levels:20 to max. 250 / 200 min-1
Shaking amplitude:25 mm
Shaking Incubators VS 45 OI and VS 150 OI with Orbital Motion  LAUDA
Shaking Incubators VS 45 OI and VS 150 OI with Orbital Motion  LAUDA
Shaking Incubators VS 45 OI and VS 150 OI with Orbital Motion  LAUDA
TypeUseful capacity lInside dimension (W x D x H) mmOutside dimensions (W x D x H) mmMax. load kgWeight kgPUOrder No.CDCPrice/Unit/EUR 
VS 45 OI43450 x 300 x 320710 x 650 x 71012701583792717,910.00Order
VS 150 OI150674 x 540 x 430930 x 890 x 820201351583792919,380.00Order
Please order trays separately: model VS 60 OI: type A000045 / model VS 45 OI: type A000046 / model VS 150 OI: type A000047.
Accessories:
Accessories for GFL shakers shaking incubators: test tube racks type A000059 and A000060 / Lauda
Accessories for shaking incubators: shaking trays / Lauda
Accessories for GFL shakers: clamps for Erlenmeyer flasks / Lauda

Follow us